Enabling Devices 1521 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Redes Enabling Devices 1521. Enabling Devices 1521 User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - EKI-1521/1522/1524

User ManualEKI-1521/1522/15241/2/4-port RS-232/422/485 Serial Device Servers

Página 2 - Product Warranty (2 years)

EKI-1521/1522/1524 User Manual 4 Ethernet protection: Built-in 1.5 KV magnetic isolation Operation Temperature: 0 ~ 60° C (32 ~ 140° F) Storage Tem

Página 3 - Safety Instructions

Chapter 22 Getting Started

Página 4

EKI-1521/1522/1524 User Manual 62.1 Understanding EKI-1521/1522/1524The EKI-1521/1522/1524 are network-based, serial device servers for connectingRS-2

Página 5 - Contents

7 EKI-1521/1522/1524 User ManualChapter 2 Getting Started2.1.2 COM Port Redirector (Virtual COM Port)Advantech Serial Device Server Configuration Util

Página 6

EKI-1521/1522/1524 User Manual 82.1.2.2 Multi-Access Mode (Shared COM port mode)Most of serial devices are connected directly and physically to the PC

Página 7 - Chapter 1

9 EKI-1521/1522/1524 User ManualChapter 2 Getting Started2.1.3 TCP Server ModeIn TCP server mode, you might initiate the TCP connection from host to E

Página 8 - 1.1 Introduction

EKI-1521/1522/1524 User Manual 102.1.5 Serial Tunneling ModeTwo native serial devices can communicate over an Ethernet network without anyintermediate

Página 9 - Chapter 1 Overview

11 EKI-1521/1522/1524 User ManualChapter 2 Getting Started2.2 HardwareIn this section, we will give you an overview of EKI-1521/1522/1524 hardware and

Página 10 - 1.4 Package Check List

EKI-1521/1522/1524 User Manual 122.2.2 Dimensions (Units: mm)2.2.2.1 EKI-1521 and EKI-1522Figure 2.7 Front View of EKI-1521/1522Figure 2.8 Side View o

Página 11 - Chapter 2

13 EKI-1521/1522/1524 User ManualChapter 2 Getting StartedFigure 2.9 Back View of EKI-1521/1522Figure 2.10 Top View of EKI-1521/1522

Página 12 - 2.1.1 Product Description

EKI-1521/1522/1524 User Manual iiCopyrightThe documentation and the software included with this product are copyrighted 2006by Advantech Co., Ltd. All

Página 13 - Chapter 2 Getting Started

EKI-1521/1522/1524 User Manual 142.2.2.2 EKI-1524Figure 2.11 Front View of EKI-1524Figure 2.12 Side View of EKI-1524

Página 14

15 EKI-1521/1522/1524 User ManualChapter 2 Getting StartedFigure 2.13 Back View of EKI-1524Figure 2.14 Top View of EKI-15242.3 Connecting HardwareNext

Página 15

EKI-1521/1522/1524 User Manual 162.3.1.1 Panel/Wall MountingThe EKI-1521/1522/1524 can be attached to a wall using the included metal brack-ets. Each

Página 16 - 2.1.7 Control Mode

17 EKI-1521/1522/1524 User ManualChapter 2 Getting StartedThen, let the device down straight to slide over the rail smoothly.Figure 2.17 DIN-rail Step

Página 17

EKI-1521/1522/1524 User Manual 182.3.4 Serial ConnectionEKI-1521/1522/1524 provides one, two, or four ports DB9 (male) connectors. RS-232/422/485 pin

Página 18 - 2.2.2 Dimensions (Units: mm)

19 EKI-1521/1522/1524 User ManualChapter 2 Getting Started4. If there is an existed COM port mapping utility on host, you have to remove this and rebo

Página 19

EKI-1521/1522/1524 User Manual 206. The InstallShield Wizard will specify a default installation path, C:\Program Files\Advantech eAutomation\Serial D

Página 20 - 2.2.2.2 EKI-1524

Chapter 33 Configuration

Página 21

EKI-1521/1522/1524 User Manual 223.1 Configuration Utility OverviewEKI-1521/1522/1524 provides an easy-to-use configuration utility to configure yours

Página 22

23 EKI-1521/1522/1524 User ManualChapter 3 Configuration3.2 Discovering Serial Device Servers3.2.1 Auto SearchingAdvantech Serial Device Server Config

Página 23

iii EKI-1521/1522/1524 User Manual Declaration of ConformityCEThis product has passed the CE test for environmental specifications when shieldedcable

Página 24 - 2.3.4 Serial Connection

EKI-1521/1522/1524 User Manual 24Select the device in this sub-tree. The first tab on the “Configuration Area” shows thesummary of “Basic Information”

Página 25

25 EKI-1521/1522/1524 User ManualChapter 3 Configuration

Página 26

EKI-1521/1522/1524 User Manual 263.2.2 Clear Device List and Search AgainYou can click the button on the “Quick Tool Area”; utility will clear all

Página 27 - Chapter 3

27 EKI-1521/1522/1524 User ManualChapter 3 Configuration3.3 Setting Ethernet ParametersThis section explains how to configure EKI-1521/1522/1524 netwo

Página 28

EKI-1521/1522/1524 User Manual 28 MAC Address: The MAC address is for the local system to identify and locate each serial device servers. This MAC ad

Página 29 - Chapter 3 Configuration

29 EKI-1521/1522/1524 User ManualChapter 3 Configuration Type: The EKI-1521/1522/1524 offers three kinds of serial protocols, RS-232, RS-422 and RS-4

Página 30

EKI-1521/1522/1524 User Manual 30 Flow Control: The EKI-1521/1522/1524 provides four options: None, XOn/XOff, RTS/CTS, and DTR/DSR.3.4.2 Setting Virt

Página 31

31 EKI-1521/1522/1524 User ManualChapter 3 ConfigurationEKI-1521/1522/1524 provides Multi-access function through one Ethernetconnection path or dual

Página 32 - 3.2.3 Manual Appending

EKI-1521/1522/1524 User Manual 323.4.3 Setting TCP/UDP Server/Client Operating Mode ParametersEKI-1521/1522/1524 provides various operating modes. Sel

Página 33

33 EKI-1521/1522/1524 User ManualChapter 3 Configuration Data Listen Port: The TCP (UDP) port number represents the source port num-ber, and the numb

Página 34 - 3.4 Setting Serial Parameters

EKI-1521/1522/1524 User Manual iv6. Put this equipment on a reliable surface during installation. Dropping it or letting it fall may cause damage.7. T

Página 35

EKI-1521/1522/1524 User Manual 343.4.4 Setting Control Operating Mode ParametersThe “Control mode” is a very special operating mode. The EKI-1521/1522

Página 36

35 EKI-1521/1522/1524 User ManualChapter 3 ConfigurationThe following commands are available for EKI-1521/1522/1524.3.5 Security Configuration3.5.1 Ac

Página 37

EKI-1521/1522/1524 User Manual 36 Allow any IP to access.

Página 38

37 EKI-1521/1522/1524 User ManualChapter 3 Configuration3.6 Fulfilling Administrator FunctionsThere have many administrator functions in Advantech Ser

Página 39

EKI-1521/1522/1524 User Manual 383.6.2 Locate Serial DeviceOnce you use this function, the device sever you chose to locate, its “Status” LED willbe l

Página 40

39 EKI-1521/1522/1524 User ManualChapter 3 Configuration3.6.5 Upgrading the FirmwareAdvantech continually upgrades its firmware to keep up with the ev

Página 41

EKI-1521/1522/1524 User Manual 402. Select the firmware you want to update.3. After downloading the firmware completely, click on the “OK” button. The

Página 42 - 3.5.2 Port Monitor

Chapter 44 Setting COM Redirector

Página 43

EKI-1521/1522/1524 User Manual 424.1 Setting COM Redirector (Virtual COM port)Advantech COM port mapping software is a serial COM port redirector that

Página 44 - 3.6.3 Lock Device

43 EKI-1521/1522/1524 User ManualChapter 4 Setting COM RedirectorThe COM ports in the “Virtual Com Ports” listing are now available for use by Win-dow

Página 45

v EKI-1521/1522/1524 User Manual ContentsChapter 1 Overview...11.1 Introduction ...

Página 46

EKI-1521/1522/1524 User Manual 444.1.2 Manual MappingRight click the serial device name on the sub-tree of Device Server List area andselect the “Manu

Página 47 - Chapter 4

45 EKI-1521/1522/1524 User ManualChapter 4 Setting COM RedirectorAuto Reconnect PropertySometimes, the connection between Advantech serial device serv

Página 48 - 4.1.1 Auto Mapping

EKI-1521/1522/1524 User Manual 464.1.3 Manual Direct Mapping Virtual COM PortClick the button on the Quick Took area, you can add a target by select

Página 49

47 EKI-1521/1522/1524 User ManualChapter 4 Setting COM Redirector4.2 Running Diagnostic TestThe purpose of this test is to make sure the communication

Página 50 - 4.1.2 Manual Mapping

EKI-1521/1522/1524 User Manual 482. Select which COM port you want to run a diagnostic test, and then press “Test” button to process the testing.Signa

Página 51

49 EKI-1521/1522/1524 User ManualChapter 4 Setting COM Redirector

Página 52

www.advantech.comPlease verify specifications before quoting. This guide is intended for referencepurposes only.All product specifications are subject

Página 53 - 4.2 Running Diagnostic Test

EKI-1521/1522/1524 User Manual vi3.3 Setting Ethernet Parameters... 273.4 Setting Seri

Página 54

Chapter 11 Overview

Página 55

EKI-1521/1522/1524 User Manual 21.1 IntroductionAdvantech's EKI series of Industrial Device Servers are a robust, feature-rich, andcost effective

Página 56

3 EKI-1521/1522/1524 User ManualChapter 1 Overview1.2 Features Expand up 255 serial ports for one Windows NT/2000/XP/Vista(X86) host Provides dual 1